Digibell Vandal Resistant System Przewodnik Instalacji Strona 52

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 51
Digibell Vandal Resistant System
PD-169 Issue 3B Installation Guide Page 52 of 56
Diagram 12 – Optional Features
Time Clock Sharing
A time clock can be shared between distributed equipment areas by borrowing one of the
‘commn -’ wires in the interconnecting Cat5 to use as the shared “Time clock common”.
The “Time clock common” signal is sharable across all BSD-DIG controllers.
Keypad Matrix
1
1 2 3 4
5
6
7
8
4
7
<A
2
5
8
0
3
6
9
>Z
X
2
2
1
1
B
B
A
A --
-
- ++
-
-
Controller Controller
Control
Area 2
Equipment
Control
Equipment
Area 1
BSD-DIG
BSD-DIG
Blu
Time Clock
Common
Time Clock
Common
Blu
W/Blu
W/Blu
Cat5
VideoVideo
Commn
Commn
Audio
Audio DataData
++
Time
Time
--
-
+
CO
NO
NC
TS2000
Time Clock
Przeglądanie stron 51