Digibell Vandal Resistant System
PD-169 Issue 3B Installation Guide Page 20 of 56
Installation & Commissioning Guide
Installation
1. Review the section headed ‘Safety information’ on Page 55.
2. Check the equipment supplied is as required; refer to the previous section if
necessary.
3. Ensure the correct cable type is used (CAT5 and 1.0mm
2
).
4. Install the system according to instructions in this section.
5. For optional wiring such as a Trades time clock, Fob reader or gate trigger relay refer
to diagrams 12, 13 or 14.
6. Fit each component, checking the maximum cable distances shown on the cable
overviews in the previous section.
Commissioning
Settings
1. Set the flat addresses of each DBA-4I or DBA-8Z Isolator referring to the following
sections.
2. Entrance and caller settings (speech time, ring time, unlock time, etc) are adjusted
through each entrance panel at the associate entrance. Refer to the ‘Entrance panel
programming’ section page 22.
3. Settings specific to each phone, such as ring volume and buzzer mute time, when
available, are set inside each phone with a jumper or Dipswitch. Refer to the ‘Phone
Settings’ section.
4. Speech levels are adjusted at each entrance panel behind the speech grill, with a
separate adjustment for each direction of speech. A howling or whistling sound may
indicate the volumes levels are set to high.
Testing / Connecting
The major components of the Digibell system are fitted with high quality pluggable screw
terminal blocks. This enables all the connections to the system to be fully completed, whilst
easily isolating individual pieces of equipment during testing and commissioning.
Any problems can be resolved by rechecking wiring and connections, assisted by the various
suggestions and tests in the section ‘Troubleshooting’.
Connect up one entrance first, leaving any connection to Isolators or phones unplugged:
1. When powered up for the first time, it is recommended that only the most basic system
is connected, i.e. 4/8 phones, 1 BSD-DIG Door controller and entrance panel, 1 DBA-
xx Isolator, the remaining equipment can be isolated by removing terminal blocks.
2. Check the display and buttons on the entrance panel work as expected.
3. If there is an exit button check the door will unlock.
4. Proceed to test the system by calling each phone from the entrance panel in the
normal way, check any available phone features such as buzzer mute or door status.
Once the basic system is fully functioning, continue to connect and test equipment
item by item until completed.
Entrance Panel
The mounting height should be considered carefully and applicable standards checked, such
as Building regulations and Disabled access. Entrance panels should have mastic applied to