Digibell Vandal Resistant System
PD-169 Issue 3B Installation Guide Page 24 of 56
LOCK – Lock Type
[Secr] = Fail secure lock: - Requires alternate mechanical means, key or thumb-turn to
open on power failure.
[Safe] = Fail safe lock: - Lock opens on power failure, this includes Maglocks.
CAM2 - Not used on the Digibell system, leave on the default of [No]
TRAD – Door Button Trades Mode (0-9, default 5)
[0] [1] [2] [3] [4]
[6] [7] [8] [9]
Off
None None None None Code
Code Trade Trade Door
On
None Door Code Trade Trade
Code Trade Door Door
‘None’ = No function; pressing the Trades button is ignored.
‘Door’ = Pressing the Trades button opens the door.
‘Code’ = Pressing the Trades button prompts for the [ACOD] access code to open the
door.
‘Trade’ = Pressing the Trades button prompts for either the [ACOD] or [TCOD] access
codes to open the door
DMON – Door Monitor Switch/Contact
[Owc] = Contacts open when door is closed: - This default allows for no switch fitted.
[Cwc] = Contacts closed when door is closed: - Standard normally closed switch.
RECP – Reception Phone Address
The Reception button is used to call a reception desk or similar. The number is that of the
called phone. The default is [9898] which is unlikely to be used by a flat.
PSEC – Panel Security Key
The security key is required to gain access to panel programming.
The code is entered then pressing the call button, the default is [3434] and it is
recommended that this be changed for security.
This code can contain letters and numbers for added security.
PPRG – Phone Programming Security Key
The phone programming security key is required to gain access to flat number programming
of telephones (not normally required). The default is [1212] and it is recommended that this
be changed for security. This code can contain letters and numbers for added security.